Browse all practice questions for the ET ASNT Level II Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ET ASNT Level II Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What impact does increasing the test frequency typically have on the eddy current testing process?
  • In which scenario is Acoustic Emission Testing most beneficial?
  • When using the eddy current method, discontinuities are most easily detected when the eddy currents are:
  • What effect does the use of magnetic shielding around the exciting coil generally have?
  • What does an eddy current test primarily detect?
  • What effect does a lower testing frequency have on eddy current penetration?
  • How does defect sizing influence overall operational reliability?
  • The impedance diagram principle states that to test all frequencies, what must lie at the same point on the diagram?
  • How does test frequency affect the depth of penetration for eddy currents?
  • What happens to the direction of eddy currents in a part when the electrical current in an eddy current coil reverses direction?
  • What corrective action does an automatic marking system enable in eddy current testing?
  • When testing magnetic materials in a magnetic field, increasing the field strength will result in:
  • If the characteristic frequency of a material is 125 Hz, what test frequency is required for an f/f ratio of 10?
  • Who is accountable for the qualifications of an ET Level II technician?
  • To decrease the effect on conductivity readings due to variations in test part thickness, one should:
  • Which symbol is commonly used to signify impedance?
  • What essential action does defect sizing facilitate in Electromagnetic Testing?
  • Why is understanding material properties important in eddy current testing?
  • For limit frequency equations to be effective, they must be:
  • What is the primary purpose of a high-pass filter in eddy current testing?
  • The impedance of a test coil usually can be represented by the vector sum of:
  • Why is calibration important in Electromagnetic Testing?
  • Which type of coil primarily relates to the fill factor term?
  • What term defines two or more coils electrically connected in opposition during testing?
  • What happens to eddy currents as the frequency of the applied magnetic field increases?
  • What principle underlies the operation of an Eddy current instrument?
  • In eddy current testing, which condition may lead to inaccurate results?
  • Which term refers to a material that has a permeability less than that of a vacuum?
  • How do ferritic materials behave concerning ET?
  • Eddy current testing is based on which principle?
  • When testing tubing with an encircling coil, the phase relationship of output signals from ID and OD discontinuities is what?
  • Which safety measure is crucial when performing Eddy current testing?
  • If the conductivity of a test part in an eddy current test coil decreases, the magnitude of the eddy currents at a given depth in the test specimen:
  • In relation to ET, what is the role of a technician during inspections?
  • Which of the following materials would have the highest resistivity value?
  • What information does the phase angle provide in defect characterization?
  • What term is used to define the timing relationships involved in alternating current signals?
  • What is the goal of using electromagnetic testing techniques?
  • Which material is most likely used as a mounting material for a probe coil?
  • What develops the magnetic field in a material placed in an applied magnetizing force (H)?
  • What type of flux is NOT included when measuring the magnetic field in ferrous materials?
  • What are the two main types of Eddy current tests?
  • Which electrical parameters are essential for interpreting eddy current signals in ET?
  • What do we call an eddy current test coil that uses magnetic material to shape the magnetic field?
  • What is a major problem with the eddy current test method?
  • What is the formula used to calculate the inductive reactance of a test coil?
  • Which factor does NOT affect the sensitivity of an Eddy current test?
  • In terms of safety, why is assessing defect their size necessary?
  • In eddy current testing of nonferrous materials, the test frequency is determined by which of the following?
  • Which body is typically involved in establishing ET Level II technician qualifications?
  • What kind of training is necessary for personnel involved in eddy current testing?
  • What is the primary limitation of Liquid Penetrant Testing?
  • What is the simplest method for measuring the thickness of nonconductive coatings on a conductive base?
  • A property of a test system that allows the separation of signals from closely located discontinuities is known as what?
  • Doubling the number of turns on a coil will have what effect on inductance?
  • What role does defect sizing play in ensuring safety during maintenance actions?
  • When using which method is it possible to separate the conductivity variable from the permeability and dimensional variables?
  • Which of the following does NOT influence the depth of penetration in Eddy current testing?
  • The selection of actual frequencies for eddy current inspection is based on:
  • What is the difference between a probe and a transducer in the context of ET?
  • How do coatings affect eddy current testing?
  • What is the skin effect in the context of Eddy current testing?
  • What impact do environmental conditions have on ET?
  • A method for minimizing the effect of indications caused by gradual dimensional changes is to:
  • In modulation analysis testing, which factor would not modulate the test frequency applied to the test coil?
  • In what scenario is the density of eddy currents at its maximum?
  • Which of the following is not a commonly used eddy current testing readout mechanism?
  • Which factor does NOT affect a metal's conductivity value?
  • Which term describes the ability of a material to create an opposing magnetic field in response to an external magnetic field?
  • When using eddy current testing with a frequency discriminating circuit, which variable is classified as high-frequency?
  • The change in impedance of an eddy current test coil due to variations in test part characteristics is usually analyzed as a change in:
  • How does the aspect ratio of a flaw influence its detectability in Eddy current testing?
  • What principle does the concept of eddy currents rely on?
  • What is one of the primary uses of AC methods in testing?
  • In eddy current testing using the ellipse method, what variable may be indicated by the size of the ellipse opening?
  • What role does grain size play in eddy current testing results?
  • Which parameter is crucial for achieving effective eddy current testing results?
  • What can improper defect sizing potentially result in?
  • What property of materials is primarily tested in Eddy Current Testing?
  • What is the significance of a calibration standard in ET?
  • Which testing method is best for detecting thin, shallow surface cracks?
  • In a setup where a 13 mm diameter bar is inserted into a 25 mm diameter coil, the fill factor is:
  • What aspect of defect sizing can affect the longevity of a structure?
  • In the context of Electromagnetic Testing, what role does software play?
  • What factor determines the frequency required for a specific eddy current testing application?
  • Why might a technician adjust the frequency during ET?
  • Which coil arrangement minimizes the effects of minor variations along the length of a wire?
  • What is the main advantage of non-destructive testing over destructive testing?
  • What should be the ratio of the specific diameter of a probe to the minimum discontinuity of interest?
  • When testing small parts in an eddy current encircling coil, which test parameter is important?
  • Which of the following methods can improve the signal-to-noise ratio in an eddy current test system?
  • What is one advantage of using digital data acquisition in ET?
  • The magnetizing force of an eddy current test coil is usually designated by which letter?
  • What does phase angle adjustment achieve in Eddy current testing?
  • What is crucial for determining the resonant frequency during eddy current testing?
  • What happens to an eddy current test coil's magnetic field intensity as the distance outside the coil increases?
  • A decrease in conductivity is equivalent to:
  • What impact does defect sizing have on regulatory compliance?
  • When a coil's magnetizing force is applied to a ferromagnetic material, the flux density in the material is:
  • What is the term for the portion of magnetic flux that passes outside of a ferrous material when a surface discontinuity is encountered?
  • What is essential for ensuring compliance with standards in ET?
  • What types of defects can eddy current testing commonly detect?
  • The term fill factor is associated with which type of coil?
  • What is the role of the test coil in ET?
  • Which type of flaw can be detected by both Ultrasonic Testing and Radiographic Testing?
  • The flux density in a magnetic material is usually designated by the:
  • How can temperature affect the results of Electromagnetic Testing?
  • In the context of eddy current testing, why is it important to achieve proper phase discrimination?
  • How does the accuracy of defect sizing affect the structure's integrity?
  • The phenomenon in which eddy currents create an opposing magnetic field is known as:
  • In a test coil with primary and secondary windings, what affects the voltage across the secondary?
  • What is the frequency ratio defined as in electromagnetic testing?
  • When a sinusoidal wave is applied in eddy current testing, what does it indicate?
  • For age hardenable aluminum and titanium alloys, changes in hardness are indicated by changes in:
  • How does material conductivity affect the results of Eddy current testing?
  • How does surface roughness affect the results in ET?
  • What is defined as any change in a sinusoidal signal when the output is not a linear reproduction of the input?
  • What is the term used to describe the B value when H field strength has returned to zero?
  • What is one common application of Eddy current testing?
  • In a bridge circuit, why are two test coils often employed?
  • Which process improves measurement accuracy in ET?
  • Which standard governs the qualification of personnel for electromagnetic testing?
  • Which of the listed materials is primarily tested using Radiographic Testing?
  • Which flaw is easiest to detect in tubing using the eddy current method with a self-comparison differential coil arrangement?
  • What term describes the technique that discriminates between variables in a test part based on phase angle changes?
  • In an unmagnetized ferromagnetic material, the magnetic domains are:
  • Which parameter is NOT typically measured in ET?
  • What kind of discontinuities can eddy current testing typically identify within conductive materials?
  • Why is report writing an essential aspect of ET?
  • Why is it crucial to assess defect severity in Electromagnetic Testing?
  • What does the term "phase shift" in eddy current testing refer to?
  • What is the purpose of using reference standards in ET?
  • How does defect sizing contribute to maintenance decisions in Electromagnetic Testing?
  • The penetration of eddy currents in a conductive material is decreased when:
  • What effect does increasing frequency have on the penetration depth in eddy current testing?
  • What does a shift in impedance during an ET inspection indicate?
  • What does higher test sensitivity in eddy current testing indicate?
  • Why are relatively low frequencies used in inspecting ferromagnetic materials?
  • How can variations in amplitude signals be interpreted?
  • What is a common maintenance procedure for Eddy current equipment?
  • What is a significant challenge when performing ET in the field?
  • Which environmental factor can particularly impact ET signal quality?
  • What term describes a surface or internal rupture caused by processing at too low a temperature?
  • What defines the phenomenon of loss of magnetism in a material due to reversed H field strength?
  • What is a significant limitation of Eddy current testing?
  • What is the primary purpose of Electromagnetic Testing (ET)?
  • The heating effect in magnetic materials caused by rotating magnetic domains can be eliminated by what method?
  • A system that indicates only the magnitude of variations in total coil impedance is called:
  • The regions in a metal showing magnetic characteristics are called:
  • What advantage does phase-sensitive detection offer in ET?
  • Which term best describes the process of applying pressure and heating materials in relation to strain testing?
  • As the fill factor decreases, how does the impedance variation of a pickup coil change with a given conductivity change?
  • In a non-destructive testing context, what is the main purpose of eddy current testing?
  • The H field value needed to reduce the remanence of a material to zero is referred to as?
  • In ET, how are defects quantified?
  • What is the basis for circuits that minimize the effect of unwanted signals on the readout mechanism?
  • If the test frequency increases while the field strength remains constant, what happens to the surface eddy current density?
  • Which factor does not affect the inductance of an eddy current test coil?
  • What happens to the eddy current flow in a conductive material as its thickness increases?
  • How does lift-off correction benefit Eddy current testing results?
  • Which element is NOT typically evaluated during Magnetic Particle Testing?
  • To eliminate dependence on the number of turns in a test coil, the inductance values on an impedance diagram are:
  • The conductivity value for a metal is influenced by which of the following factors?
  • Which measurement is crucial for assessing the effectiveness of an eddy current testing setup?
  • Which of the following methods is primarily used for non-destructive testing?
  • Which factor could lead to ineffective maintenance plans?
  • What is a characteristic of an eddy current testing probe?
  • What is the term used for a surface coil that can be rotated about the circumference of a test specimen?
  • What unit is the inductive reactance of a coil measured in?
  • What is the result of a condition where there is excessive working or metal movement during forging, rolling, or extruding operations?
  • What term describes the effect observed from a change in electromagnetic coupling as the distance between a test specimen and a probe coil is varied?
  • When using the linear time-base method in eddy current testing, what is applied to the vertical deflection plates when conditions are balanced?
  • In ET, what does the term "frequency" refer to?
  • In eddy current testing using the linear time-base method, what is applied when there is an unbalance condition between the test specimen and reference standard?
  • The induction field B within a material, when the H field strength returns to zero, is commonly referred to as?
  • Why is Eddy current testing conducted at various frequencies?
  • Variations in the test material during an eddy current test can be detected as variations in what?
  • What is the primary difference between AC and DC methods in electromagnetic testing?
  • What is a direct outcome of effective defect sizing?
  • What type of force interacts in electromagnetic induction processes as observed in eddy current testing?
  • The skin depth in a conductive material is primarily affected by what factor?
  • In an eddy current testing scenario, as coil diameter increases, what typically occurs?
  • Which type of coils are generally used for tubing inspection?
  • An out-of-phase condition between current and voltage in an eddy current coil can exist in which of the following?
  • Which three major specimen parameters influence eddy current testing?
  • When the voltage applied to a circuit and the current through the circuit both reach their maximums and minimums at the same time, the voltage and current are:
  • What factor does NOT affect defect detection in ET?
  • When performing dye penetrant testing, what is the purpose of the emulsifier?
  • What is the purpose of conducting multi-frequency Eddy current tests?
  • The phenomenon where, at very high frequencies, the eddy current flow is restricted to an extremely thin outer layer of the conductor is called:
  • When selecting specimens as reference standards, which condition is least important?
  • The ratio of a material's flux density to a test coil's magnetizing force (B/H) can be used to determine the material's:
  • Where will the density of eddy currents be the greatest when a rod is placed in an encircling type of coil?
  • During the eddy current inspection process, what kind of materials can significantly hinder testing performance?
  • Which method is characterized by being a subdivision of the phase analysis method of testing?
  • What principle allows for testing with similar geometry under cylindrical or spherical symmetry?
  • Which of the following is a limitation of Eddy current testing?
  • Which of the following is a benefit of accurate defect sizing in electromagnetic testing?
  • Which device can be used to suppress unwanted high-frequency harmonics?
  • The magnetic field generated by eddy currents induced in a test specimen:
  • How can magnetic permeability be measured using ET?
  • What must limit frequency equations be used for to be considered useful?
  • In ultrasonic testing, what does the term 'couplant' refer to?
  • What is the normal indication when using the ellipse method in eddy current testing and the test specimen matches the reference standard?
  • Which factor does NOT impact the resolution of an eddy current testing system?
  • During eddy current testing, what signifies the presence of defects in the test specimen?
  • What does the term "lift-off" refer to in eddy current testing?
  • What impact does material structure have on eddy current testing results?
  • Why is defect sizing important in Electromagnetic Testing?
  • What does volumetric defect detection focus on in ET?
  • An eddy current system that includes automatic marking of defective areas primarily allows you to:
  • What type of data is generated from an eddy current test?
  • What is a primary benefit of using phased array technology in ET?
  • In eddy current testing, how is the specimen coupled to the test coil?
  • What does the term "crossover" indicate in Eddy current testing?
  • What is the ultimate goal of defect sizing in the context of Electromagnetic Testing?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy